For development of any module first step is to get Module Prefix Code (MPC) from VIENNA. 

 

Note:  

  • Module prefix code should not be less than five character. 

  • Suppose VAT is given module prefix code to any client. Then user create first module with prefix VAT01 and second module with prefix VAT02 and so on. 
     

Prefix is the base for any Module in Vienna. At present there are Modules available in the Market and all with the unique prefixes. To name few of them like VAT01_ , VAHRUAE_ etc. 

For development of any module first step is to get module prefix code from VIENNA. You can also choose your prefix name and send to us so that Vienna will reserve that prefix for your module and not allocate that name to any other module. Prefix is uniquely defines a module separate from other modules. 

 

Here is a list of Tables and respective windows where prefix is require: 

Window Name 

 

Table name 

 

Column 

 

Description 

 

Table and Column 

 

AD_Table 

 

DB Table Name 

 

On creating table use prefix code + “_”  

for DB Table Name for example if  

table name is ‘TaxMaster’.  

Then after use prefix it became  

‘VAT01_TaxMaster’. VAT is prefix unique code 

 

System Element 

 

AD_Element   

 

DB Column Name 

On creating system element use prefix  

code+ “_” for DB Column Name like column  

name is Description then it becomes  VAT01_Description. 

 

Table and Column 

 

AD_Column 

 

DB Column Name 

 

On creating column use prefix code + “_” for DB Column Name 

 

Message 

 

AD_Message  

 

Value 

 

On creating message use prefix code+ “_” for Value field 

 

 

AD_Reference 

 

Name 

 

On creating reference use prefix code+ “_” for name field 

 

Window, Tab & Field 

 

AD_Window 

 

Name 

 

On creating window, use prefix code + “_” for window name 

 

Report & Process 

 

AD_Process 

 

Name, Value 

 

Use prefix code+ “_” for name and value filed in window Report & Process 

 

Form 

 

AD_Form 

 

Name 

 

Use prefix code + “_” for Name field in F Form window 

 

Shortcut 

 

AD_Shortcut 

 

Name 

 

Use prefix code + “_” for Shortcut name 

 

Print Format 

 

AD_PrintFormat 

 

Name 

 

Use prefix code + “_” for name 

 

Report Format 

 

AD_ReportFormat  

 

Name 

 

User prefix code+ “_” for name 

 

Workflow 

 

AD_Workflow 

 

Name, Value 

 

Use prefix code+ “_” for Name and Value 

 

Validation Rules 

 

AD_Val_Rule 

 

Name 

 

Use prefix code+ “_” for Name